arrows arrow-right arrow-left menu search rss youtube linkedin twitter facebook arrow-play

Dual-Sensing Modalities  

Addressing the challenging task of explosive detection in liquids.
Watch Video

Battelle LS10™ Technical Specifications

Technology
Radio frequency and ultrasonic wave interrogation 

Weight
37 pounds (17 kilograms)

Size
Table-top footprint of about 20" x 21" x 18" tall (51cm x 53cm x 46cm tall)

Sample interface
Interrogates liquids, aerosols, and gels in glass, plastic, metal, ceramic and paper containers non-invasively. Total analysis time is less than 5 seconds.

Safety declaration
Emits no ionizing radiation and does not produce any laser light

Operational ranges
Temperature ranges from 32°F (0°C) to 104°F (40°C). Humidity ranging from 0% to 98%. Altitude ranging from 300 feet to (91 meters) below to 5,000 feet (1,524 meters) above sea level.

Storage ranges
Temperature raging from -19°F (-7°C) to 120°F (49°C). Humidity ranges from 0% to 98%. Altitude ranges from 300 feet (91 meters) below to 10,200 feet (3,109 meters) above sea level.

User interface
Touch-screen application in a familiar computer environmental at comfortable desktop height 

Alarms 
Signals a detection event with visible and audible signals

Calibration
Calibrated at the factory, but a system test is recommended at start-up and after every 24 hours of operation. Calibration is complete in less than 2 minutes.

Clear-down time
Less than 10 seconds

Power
110 to 240 VAC at 60 Hz and 50 Hz 

External data interface
USB support, network compatible

Updates and data 
USB allows software updates and data downloads